Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.943
Filtrar
1.
PLoS One ; 19(4): e0302123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630708

RESUMO

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Gravidez , Feminino , Humanos , Idade Gestacional , Projetos Piloto , Reprodutibilidade dos Testes , Estudos de Viabilidade , Estudos Prospectivos , Ecocardiografia/métodos , Ventrículos do Coração , Ecocardiografia Tridimensional/métodos
2.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38527004

RESUMO

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cateteres , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Early Hum Dev ; 191: 105985, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38513546

RESUMO

BACKGROUND: Increased left atrial volume (LAV) is a marker of cardiovascular risk. Echocardiography standards to assess LAV in adults and children are the biplane area-length method (AL) and method of disks (MOD). LAV in neonatology is usually derived as M-mode ratio between the LA and the Aorta (LAAo). The aim of this study is to determine feasibility and reliability of these methods in neonatal clinical practice. METHODS: Clinically indicated echocardiograms in neonatal intensive care patients were retrospectively analyzed. Feasibility was determined with an image quality score describing insonation angle, foreshortening and wall clarity. Reliability was determined with Bland-Altman and correlation coefficient analysis of intra- and inter-observer measurements. RESULTS: 104 infants ranging from 23 to 39 weeks gestation were included. The feasibility of LAAo, AL and MOD was comparable (median image score 4 out of 6 points). Linear regression between AL and MOD was excellent (R2 0.99). LAAo best-fit with MOD was reached with curve-linear regression (R2 0.28) whereby a LAAo of 1.60 correlated with 1.24 ml/kg, but with a wide 95 % CI. The correlation coefficient within and between observers for LAAo, biplane AL, biplane MOD and monoplane MOD was 0.93 (0.87-0.96), 0.98 (0.96-0.99), 0.98 (0.96-0.99), 0.99 (0.97-0.99) and 0.58 (0.11-0.81), 0.75 (0.44-0.89), 0.92 (0.88-0.98), 0.96 (0.88-0.98) respectively. CONCLUSION: All methods were equally feasible and reliable when repeated by the same observer, but LAAo reliability was poor when repeated by a different observer. Biplane MOD was the most reliable and thus recommended in neonatal practice. Monoplane MOD performed well and could be considered as alternative but might be less accurate.


Assuntos
Ecocardiografia Tridimensional , Adulto , Criança , Recém-Nascido , Humanos , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes , Terapia Intensiva Neonatal , Estudos Retrospectivos , Átrios do Coração/diagnóstico por imagem
4.
Echocardiography ; 41(3): e15798, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516863

RESUMO

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Fotografação
5.
BMC Med Imaging ; 24(1): 61, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481130

RESUMO

OBJECTIVE: The paper aimed to improve the accuracy limitations of traditional two-dimensional ultrasound and surgical procedures in the diagnosis and management of congenital heart disease (chd), and to improve the diagnostic and therapeutic level of chd. METHOD: This article first collected patient data through real-time imaging and body surface probes, and then diagnosed 150 patients using three-dimensional echocardiography. In order to verify the effectiveness of the combination therapy, 60 confirmed patients were divided into a control group and an experimental group. The control group received conventional two-dimensional ultrasound and surgical treatment, while the experimental group received three-dimensional ultrasound and image guided surgical treatment. RESULT: In the second diagnosis, the diagnostic accuracy of type 1, type 2, and type 3 in the control group was 84.21%, 84.02%, and 83.38%, respectively. The diagnostic accuracy rates of type 1, type 2, and type 3 in the experimental group were 92.73%, 92.82%, and 92.83%, respectively. In the control group, 2 males and 1 female experienced heart failure after surgery. However, in the experimental group, 0 males and 0 females experienced heart failure after surgery. CONCLUSION: The combination of three-dimensional echocardiography and image guided surgery can improve diagnostic accuracy and surgical treatment effectiveness, thereby reducing risks and complications, and improving surgical success rate.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias Congênitas , Insuficiência Cardíaca , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia Tridimensional/métodos , Ultrassonografia
6.
Kardiologiia ; 64(2): 73-79, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38462807

RESUMO

AIM: Vitamin D deficiency has a high prevalence in the population and is highly associated with cardiovascular diseases. The aim of this study was to evaluate subclinical left ventricular (LV) function using strain analysis in healthy individuals with vitamin D deficiency. MATERIAL AND METHODS: 113 healthy volunteers were enrolled in the study (age, 44.1±7 yrs, 34 male). All volunteers underwent two-dimensional (2D) and three-dimensional (3D) speckle tracking echocardiography after conventional echocardiographic evaluation. The subjects were divided into two groups according to their vitamin D concentrations. 61 subjects with vitamin D less than 20 ng / ml were included in the vitamin D deficiency group. The baseline clinical characteristics, laboratory measurements, echocardiographic data, including 2D and 3D global longitudinal strain (GLS) values, were compared between the groups. RESULTS: The 2D GLS values of the subjects with vitamin D deficiency were lower (mathematically less negative) than subjects with normal vitamin D (-16.1±3.4 vs -19.3±4.2, p<0.001). Similarly, the 3D GLS results were lower in subjects with vitamin D deficiency (-18.3±5.2 vs -24.1±6.9, p<0.001). A significant correlation was detected between the vitamin D concentrations and the 2D and 3D GLS measurements. (r=0.765 and r=0.628, respectively, p<0.001). Vitamin D was found to be an independent predictor of impaired 2D and 3D LV GLS (p=0.031, p=0.023, respectively). CONCLUSION: Subclinical LV dysfunction in healthy individuals with vitamin D deficiency was demonstrated by 3D and 2D strain analysis. Due to potential negative effects of vitamin D deficiency on cardiac function, more attention should be paid to healthy individuals with vitamin D deficiency.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias , Disfunção Ventricular Esquerda , Deficiência de Vitamina D , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Função Ventricular Esquerda , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/diagnóstico , Vitamina D
7.
Ultrasound Med Biol ; 50(5): 661-670, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38341361

RESUMO

OBJECTIVE: Valvular heart diseases (VHDs) pose a significant public health burden, and deciding the best treatment strategy necessitates accurate assessment of heart valve function. Transthoracic echocardiography (TTE) is the key modality to evaluate VHDs, but the lack of standardized quantitative measurements leads to subjective and time-consuming assessments. We aimed to use deep learning to automate the extraction of mitral valve (MV) leaflets and annular hinge points from echocardiograms of the MV, improving standardization and reducing workload in quantitative assessment of MV disease. METHODS: We annotated the MV leaflets and annulus points in 2931 images from 127 patients. We propose an approach for segmenting the annotated features using Attention UNet with deep supervision and weight scheduling of the attention coefficients to enforce saliency surrounding the MV. The derived segmentation masks were used to extract quantitative biomarkers for specific MV leaflet scallops throughout the heart cycle. RESULTS: Evaluation performance was summarized using a Dice score of 0.63 ± 0.14, annulus error of 3.64 ± 2.53 and leaflet angle error of 8.7 ± 8.3°. Leveraging Attention UNet with deep supervision robustness of clinically relevant metrics was improved compared with UNet, reducing standard deviations by 2.7° (angle error) and 0.73 mm (annulus error). We correctly identified cases of MV prolapse, cases of stenosis and healthy references from a clinical material using the derived biomarkers. CONCLUSION: Robust deep learning segmentation and tracking of MV morphology and motion is possible by leveraging attention gates and deep supervision, and holds promise for enhancing VHD diagnosis and treatment monitoring.


Assuntos
Aprendizado Profundo , Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Biomarcadores , Ecocardiografia Transesofagiana/métodos
8.
Echocardiography ; 41(2): e15776, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38353371

RESUMO

OBJECTIVE: Our goal was to use three dimensional (3D) strain analysis to evaluate myocardial function and ascending aorta elasticity changes in juvenile dermatomyositis (JDM). METHODS: Between 2019 and 2021, 23 JDM patients and 20 healthy volunteers participated. Both groups underwent 2D and 3D strain analysis, assessing aortic stiffness using aortic distensibility, stiffness index, strain, and elastic modulus. RESULTS: JDM patients had a median age of 13.3 ± 5.2 years, while controls had a median age of 13.8 ± 4.76 years. 3D strain analysis revealed significantly lower global longitudinal (GLS) and circumferential strain (GCS) in JDM patients compared to controls. Specifically, 3D GLS was notably reduced in patients (-28.1% vs. -31%, p = .047) compared to controls, and 3D GCS was also lower in patients (-27.5% vs. -30.5%, p = .019) compared to controls. Aortic strain and elastic modulus were significantly lower in JDM patients, while aortic stiffness index and distensibility showed no significant differences. Correlation analyses within the JDM group revealed a negative correlation between 3D GLS and age at diagnosis (r = -.561, p = .04), as well as a positive correlation between 3D GLS and both aortic strain (r = .514, p = .0001) and elastic modulus (r = .320, p = .03) in JDM patients. CONCLUSION: Our study demonstrated a trend towards lower ejection fraction and strain in patients with JDM, along with increased aortic stiffness using 3D echocardiography. These findings suggest potential cardiovascular involvement in juvenile dermatomyositis, emphasizing the importance of comprehensive cardiac assessments in these patients.


Assuntos
Dermatomiosite , Ecocardiografia Tridimensional , Rigidez Vascular , Humanos , Criança , Adolescente , Dermatomiosite/complicações , Dermatomiosite/diagnóstico por imagem , Coração , Ecocardiografia Tridimensional/métodos , Módulo de Elasticidade , Função Ventricular Esquerda
9.
J Am Soc Echocardiogr ; 37(4): 408-419, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38244817

RESUMO

BACKGROUND: The assessment of ventricular secondary mitral regurgitation (v-SMR) severity through effective regurgitant orifice area (EROA) and regurgitant volume (RegVol) calculations using the proximal isovelocity surface area (PISA) method and the two-dimensional echocardiography volumetric method (2DEVM) is prone to underestimation. Accordingly, we sought to investigate the accuracy of the three-dimensional echocardiography volumetric method (3DEVM) and its association with outcomes in v-SMR patients. METHODS: We included 229 patients (70 ± 13 years, 74% men) with v-SMR. We compared EROA and RegVol calculated by the 3DEVM, 2DEVM, and PISA methods. The end point was a composite of heart failure hospitalization and death for any cause. RESULTS: After a mean follow-up of 20 ±11 months, 98 patients (43%) reached the end point. Regurgitant volume and EROA calculated by 3DEVM were larger than those calculated by 2DEVM and PISA. Using receiver operating characteristic curve analysis, both EROA (area under the curve, 0.75; 95% CI, 0.68-0.81; P = .008) and RegVol (AUC, 0.75; 95% CI, 0.68-0.82; P = .02) measured by 3DEVM showed the highest association with the outcome at 2 years compared to PISA and 2DEVM (P < .05 for all). Kaplan-Meier analysis demonstrated a significantly higher rate of events in patients with EROA ≥ 0.3 cm2 (cumulative survival at 2 years: 28% ± 7% vs 32% ± 10% vs 30% ± 11%) and RegVol ≥ 45 mL (cumulative survival at 2 years: 21% ± 7% vs 24% ± 13% vs 22% ± 10%) by 3DEVM compared to those by PISA and 2DEVM, respectively. In Cox multivariable analysis, 3DEVM EROA remained independently associated with the end point (hazard ratio, 1.02, 95% CI, 1.00-1.05; P = .02). The model including EROA by 3DEVM provided significant incremental value to predict the combined end point compared to those using 2DEVM (net reclassification index = 0.51, P = .003; integrated discrimination index = 0.04, P = .014) and PISA (net reclassification index = 0.80, P < .001; integrated discrimination index = 0.06, P < .001). CONCLUSIONS: Effective regurgitant orifice area and RegVol calculated by 3DEVM were independently associated with the end point, improving the risk stratification of patients with v-SMR compared to the 2DEVM and PISA methods.


Assuntos
Ecocardiografia Tridimensional , Insuficiência Cardíaca , Insuficiência da Valva Mitral , Masculino , Humanos , Feminino , Insuficiência da Valva Mitral/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Curva ROC , Índice de Gravidade de Doença
10.
Lupus ; 33(2): 155-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38182135

RESUMO

BACKGROUND: Systemic lupus erythematosus (SLE) is a complex autoimmune connective tissue disease (CTD) that is an important cause of devastating pulmonary arterial hypertension (PAH), and persistent progression of PAH can lead to right heart failure, predicting a poor prognosis for SLE patients. Right ventricular-pulmonary arterial (RV-PA) coupling with echocardiography has been demonstrated to be a noninvasive alternative method for evaluating PAH patients' predictive outcomes. Whether the ratio of right ventricular stroke volume (RVSV) to right ventricular end-systolic volume (RVESV) measured by three-dimensional echocardiography (3DE) is a new index of RV-PA coupling has not been discussed as a new predictor for the clinical outcome of systemic lupus erythematosus-associated pulmonary arterial hypertension (SLE-PAH). METHODS: From June 2019 to February 2023, 46 consecutive patients with SLE-PAH were enrolled prospectively, and their clinical data and echocardiographs were studied and analyzed. The control group consisted of 30 healthy subjects matched for age, sex, and body surface area (BSA). The main endpoints of this study were a composite of all-cause mortality and adverse clinical events. Baseline clinical characteristics and echocardiographic assessments were analyzed. RESULTS: During a median of 24 months (IQR 18-31), 16 of 46 SLE-PAH patients (34.7%) experienced endpoint-related events. At baseline, patients who experienced mortality or adverse events had a worse WHO functional class (WHO FC) and lower anti-double-stranded DNA (dsDNA) antibody levels. The right ventricular (RV) systolic dysfunction in SLE-PAH subjects was significantly worse than that in the healthy control group, especially in SLE-PAH patients in the endpoint event group. Compared to controls, patients with SLE-PAH had a lower RVSV/RVESV ratio. In the group comparison, patients who had experienced an endpoint event had a sequentially worse ratio (1.86 (1.65-2.3) versus 1.30 (1.09-1.46) versus 0.64 (0.59-0.67), p < .001). There were statistically significant associations between the RVSV/RVESV ratio to routine RV systolic function and clinical parameters. The RVSV/RVESV ratio was negatively correlated with the WHO FC (r = -0.621, p < .001) and positively correlated with the anti-dsDNA level. The ROC curve showed that the optimal cutoff for RVSV/RVESV < 0.712 determined a higher risk of poor prognosis. Kaplan‒Meier survival curves showed that an RVSV/RVESV ratio >0.712 was associated with more favorable long-term outcomes. CONCLUSIONS: The 3DE-derived SV/ESV ratio as a noninvasive alternative surrogate of RV-PA coupling was an eximious indicator for identifying endpoint events in SLE-PAH patients and can provide a diagnostic basis for clinical intervention.


Assuntos
Ecocardiografia Tridimensional , Hipertensão Pulmonar , Lúpus Eritematoso Sistêmico , Hipertensão Arterial Pulmonar , Disfunção Ventricular Direita , Humanos , Hipertensão Pulmonar/etiologia , Lúpus Eritematoso Sistêmico/complicações , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Disfunção Ventricular Direita/etiologia
11.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288512

RESUMO

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Assuntos
Valvuloplastia com Balão , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Humanos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Eletrocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
12.
Clin Res Cardiol ; 113(3): 367-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37079054

RESUMO

INTRODUCTION: Real-time three-dimensional echocardiography (RT3DE) is currently being developed to overcome the challenges of two-dimensional echocardiography, as it is a much cheaper alternative to the gold standard imaging method, cardiac magnetic resonance (CMR). The aim of this meta-analysis is to validate RT3DE by comparing it to CMR, to ascertain whether it is a practical imaging method for routine clinical use. METHODS: A systematic review and meta-analysis method was used to synthesise the evidence and studies published between 2000 and 2021 were searched using a PRISMA approach. Study outcomes included left ventricular end-systolic volume (LVESV), left ventricular end-diastolic volume (LVEDV), left ventricular ejection fraction (LVEF), left ventricular mass (LVM), right ventricular end-systolic volume (RVESV), right ventricular end-diastolic volume (RVEDV) and right ventricular ejection fraction (RVEF). Subgroup analysis included study quality (high, moderate), disease outcomes (disease, healthy and disease), age group (50 years old and under, over 50 years), imaging plane (biplane, multiplane) and publication year (2010 and earlier, after 2010) to determine whether they explained the heterogeneity and significant difference results generated on RT3DE compared to CMR. RESULTS: The pooled mean differences for were - 5.064 (95% CI - 10.132, 0.004, p > 0.05), 4.654 (95% CI - 4.947, 14.255, p > 0.05), - 0.783 (95% CI - 5.630, 4.065, p > 0.05, - 0.200 (95% CI - 1.215, 0.815, p > 0.05) for LVEF, LVM, RVESV and RVEF, respectively. We found no significant difference between RT3DE and CMR for these variables. Although, there was a significant difference between RT3DE and CMR for LVESV, LVEDV and RVEDV where RT3DE reports a lower value. Subgroup analysis indicated a significant difference between RT3DE and CMR for studies with participants with an average age of over 50 years but no significant difference for those under 50. In addition, a significant difference between RT3DE and CMR was found in studies using only participants with cardiovascular diseases but not in those using a combination of diseased and healthy participants. Furthermore, for the variables LVESV and LVEDV, the multiplane method shows no significant difference between RT3DE and CMR, as opposed to the biplane showing a significant difference. This potentially indicates that increased age, the presence of cardiovascular disease and the biplane analysis method decrease its concordance with CMR. CONCLUSION: This meta-analysis indicates promising results for the use of RT3DE, with limited difference to CMR. Although in some cases, RT3DE appears to underestimate volume, ejection fraction and mass when compared to CMR. Further research is required in terms of imaging method and technology to validate RT3DE for routine clinical use.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Direita , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração , Espectroscopia de Ressonância Magnética
13.
Am J Cardiol ; 211: 287-290, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37952755

RESUMO

We aim to evaluate the reliability and consistency of measuring the aortic valve area (AVA) using 3-dimensional (3D) transesophageal echocardiography and compare it with invasive and noninvasive methods using a continuity equation (CE). Measurements were taken from 119 patients with different severity of aortic stenosis and with normal aortic valve who underwent elective transesophageal echocardiography encompassing the whole spectrum of aortic opening. Three methods were compared to determine AVA. First, the effective AVA was calculated with the standard CE, where the left ventricular outflow tract area was calculated from its 2-dimensional diameter (AVA-CEstd). Second, a modified CE method (AVA-CEmod) was used, in which the left ventricular outflow tract area was measured using 3D-multiplane reconstruction. Third, the geometric AVA was directly measured using 3D-multiplane reconstruction planimetry (AVA-3D). Interobserver and intraobserver variability were analyzed using intraclass correlation coefficients (ICCs). The values were measured by two blinded readers for interobserver variability and by one observer on the same dataset. AVA-3D was significantly larger than AVA-CEmod and AVA-CEstd (1.87 ± 1.00 cm2 vs 1.81 ± 0.92 cm2 p = 0.03 and 1.87 ± 1.00 cm2 vs 1.71 ± 0.85 cm2 p <0.001). However, in the subset of patients with AVA-3D <1.5 cm2, there was no significant difference between AVA-3D and AVA-CEmod (1.06 ± 0.24 vs 1.08 ± 0.26 cm2, paired t test: t = 0.77, degree of freedom = 58, p = 0.44). The ICC between the measurements of AVA-3D and AVA-CEmod (ICC 0.979), and AVA-3D and AVA- CEstd (ICC 0.940), were excellent. AVA-3D delivers very similar results as compared with more established echocardiographic parameters. The difference between effective and geometric AVA did not appear to be clinically relevant in patients with a higher degree of stenosis.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia Tridimensional , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Reprodutibilidade dos Testes , Ecocardiografia Tridimensional/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos
14.
J Am Soc Echocardiogr ; 37(3): 328-337, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37972791

RESUMO

BACKGROUND: Iatrogenic mitral stenosis is a complication associated with transcatheter edge-to-edge mitral valve repair. Some reports revealed the impact of mean transmitral pressure gradient after procedure on long-term clinical outcomes. However, the association between prognosis and mitral valve orifice area (MVA) after the procedure has been poorly studied. This study aimed to investigate the association between postprocedural small MVA, derived from three-dimensional (3D) transesophageal echocardiography (TEE), and long-term clinical outcomes in 2 cohorts: the degenerative mitral regurgitation (MR) cohort and the functional MR cohort. METHODS: This retrospective study assessed 279 consecutive patients with 3D TEE data during transcatheter edge-to-edge mitral valve repair between January 2010 and December 2016. Mitral valve orifice area after device implantation was measured by 3D planimetry. The patients with degenerative and functional MR were stratified separately into 2 groups according to postprocedural MVA: normal MVA (MVA > 1.5 cm2) group and small MVA (MVA ≤ 1.5 cm2) group. RESULTS: Of the 279 patients, 142 (51%) had degenerative MR and 137 (49%) had functional MR. The number of degenerative MR patients with small MVA was 38, whereas 42 patients were in the functional MR cohort. Patients with small MVA had higher rate of all-cause mortality in the degenerative MR group (log-rank test: P = .01) but not in the functional MR group (log-rank test: P = .52). In multivariate analysis small MVA was independently associated with all-cause mortality but not postprocedural transmitral pressure gradient. Neither small MVA nor transmitral pressure gradient was associated with all-cause mortality in patients with functional MR. CONCLUSION: Small MVA measured by 3D TEE after transcatheter mitral edge-to-edge repair was associated with poor prognosis in patients with degenerative MR.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ecocardiografia Tridimensional/métodos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
15.
J Clin Ultrasound ; 52(2): 178-185, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37997020

RESUMO

INTRODUCTION: The functioning of the left atrium (LA) is partly controlled by the neural system. It was purposed to evaluate correlations between the result of Ewing's 5 standard cardiovascular reflex tests (SCRTs) characterizing autonomic function and LA volumetric and functional features as assessed by three-dimensional speckle-tracking echocardiography (3DSTE) in healthy individuals. MATERIALS AND METHODS: The current study comprised 18 healthy volunteers being in sinus rhythm (mean age: 35 ± 12 years, 10 men). Measurement of blood pressure, ECG, 5 SCRTs, two-dimensional Doppler echocardiography and 3DSTE were performed. These parameters were in normal ranges in all cases. RESULTS: From LA volumetric parameters, only systolic total atrial emptying fraction (r = 0.559, p = 0.037) and early diastolic passive atrial emptying fraction (r = 0.539, p = 0.047) correlated with systolic blood pressure response to standing representing sympathetic autonomic function. From LA strains, peak mean segmental LA radial strain (RS) (r = -0.532, p = 0.050), global and mean segmental LA circumferential strain (CS) (r = 0.662, p = 0.010 and r = 0.635, p = 0.015, respectively) representing systolic LA function correlated with Valsalva ratio representing parasympathetic autonomic function. Global LA-RS (r = -0.713, p = 0.040) and LA-CS (r = 0.657, p = 0.011) and mean segmental LA-CS (r = 0.723, p = 0.003) at atrial contraction representing end-diastolic atrial contraction showed correlations with Valsalva ratio, as well. Peak global and mean segmental LA-CS (r = 0.532, p = 0.050 and r = 0.530, p = 0.050) and the same strains at atrial contraction (r = 0.704, p = 0.005 and r = 0.690, p = 0.006) representing systolic function and end-diastolic atrial contraction correlated with systolic blood pressure response to standing representing both parasympathetic and sympathetic autonomic functions. CONCLUSIONS: Significant correlations between features of vegetative autonomic function represented by Ewing's 5 SCRTs and specific LA functions represented by 3DSTE-derived LA volume-based functional properties and strains could be demonstrated in healthy adults.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Tridimensional , Adulto , Masculino , Humanos , Adulto Jovem , Pessoa de Meia-Idade , Função do Átrio Esquerdo/fisiologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Ecocardiografia Doppler/métodos
16.
J Am Soc Echocardiogr ; 37(2): 259-267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37995938

RESUMO

BACKGROUND: The dynamic shape of the normal adult mitral annulus has been shown to be important to mitral valve function. However, annular dynamics of the healthy mitral valve in children have yet to be explored. The aim of this study was to model and quantify the shape and major modes of variation of pediatric mitral valve annuli in four phases of the cardiac cycle using transthoracic echocardiography. METHODS: The mitral valve annuli of 100 children and young adults with normal findings on three-dimensional echocardiography were modeled in four different cardiac phases using the SlicerHeart extension for 3D Slicer. Annular metrics were quantified using SlicerHeart, and optimal normalization to body surface area was explored. Mean annular shapes and the principal components of variation were computed using custom code implemented in a new SlicerHeart module (Annulus Shape Analyzer). Shape was regressed over metrics of age and body surface area, and mean shapes for five age-stratified groups were generated. RESULTS: The ratio of annular height to commissural width of the mitral valve ("saddle shape") changed significantly throughout age for systolic phases (P < .001) but within a narrow range (median range, 0.20-0.25). Annular metrics changed statistically significantly between the diastolic and systolic phases of the cardiac cycle. Visually, the annular shape was maintained with respect to age and body surface area. Principal-component analysis revealed that the pediatric mitral annulus varies primarily in size (mode 1), ratio of annular height to commissural width (mode 2), and sphericity (mode 3). CONCLUSIONS: The saddle-shaped mitral annulus is maintained throughout childhood but varies significantly throughout the cardiac cycle. The major modes of variation in the pediatric mitral annulus are due to size, ratio of annular height to commissural width, and sphericity. The generation of age- and size-specific mitral annular shapes may inform the development of appropriately scaled absorbable or expandable mitral annuloplasty rings for children.


Assuntos
Ecocardiografia Tridimensional , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Adulto Jovem , Humanos , Criança , Valva Mitral/cirurgia , Ecocardiografia , Ecocardiografia Tridimensional/métodos
17.
Pediatr Cardiol ; 45(1): 213-215, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37930376

RESUMO

Three-dimensional intracardiac echocardiography (3D ICE) has gained popularity in interventional cardiology given its improved spatial and temporal imaging in assessing intracardiac anatomy pre- and post-intervention. We describe the use of 3D ICE in the reduction of a Fontan fenestration with an Occlutech atrial flow regulator (AFR) device.


Assuntos
Ecocardiografia Tridimensional , Átrios do Coração , Humanos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Ecocardiografia Tridimensional/métodos , Cateterismo Cardíaco
18.
Eur Heart J Cardiovasc Imaging ; 25(2): 152-160, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37602694

RESUMO

AIMS: Right ventricular (RV) functional assessment is mainly limited to its longitudinal contraction. Dedicated three-dimensional echocardiography (3DE) software enabled the separate assessment of the non-longitudinal components of RV ejection fraction (EF). The aims of this study were (i) to establish normal values for RV 3D-derived longitudinal, radial, and anteroposterior EF (LEF, REF, and AEF, respectively) and their relative contributions to global RVEF, (ii) to calculate 3D RV strain normal values, and (iii) to determine sex-, age-, and race-related differences in these parameters in a large group of normal subjects (WASE study). METHODS AND RESULTS: 3DE RV wide-angle datasets from 1043 prospectively enrolled healthy adult subjects were analysed to generate a 3D mesh model of the RV cavity (TomTec). Dedicated software (ReVISION) was used to analyse RV motion along the three main anatomical planes. The EF values corresponding to each plane were identified as LEF, REF, and AEF. Relative contributions were determined by dividing each EF component by the global RVEF. RV strain analysis included longitudinal, circumferential, and global area strains (GLS, GCS, and GAS, respectively). Results were categorized by sex, age (18-40, 41-65, and >65 years), and race. Absolute REF, AEF, LEF, and global RVEF were higher in women than in men (P < 0.001). With aging, both sexes exhibited a decline in all components of longitudinal shortening (P < 0.001), which was partially compensated in elderly women by an increase in radial contraction. Black subjects showed lower RVEF and GAS values compared with white and Asian subjects of the same sex (P < 0.001), and black men showed significantly higher RV radial but lower longitudinal contributions to global RVEF compared with Asian and white men. CONCLUSION: 3DE evaluation of the non-longitudinal components of RV contraction provides additional information regarding RV physiology, including sex-, age-, and race-related differences in RV contraction patterns that may prove useful in disease states involving the right ventricle.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Direita , Adulto , Masculino , Humanos , Feminino , Idoso , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Volume Sistólico/fisiologia , Envelhecimento , Função Ventricular Direita/fisiologia
19.
Eur Heart J Cardiovasc Imaging ; 25(2): 278-284, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37758446

RESUMO

AIMS: The accuracy and reproducibility of echocardiography to quantify left ventricular ejection fraction (LVEF) is limited due to image quality. High-definition blood flow imaging is a new technique which improves cavity delineation without the need for medication or intravenous access. We sought to examine the impact of high-definition blood flow imaging on accuracy and reproducibility of LV systolic function assessment. METHODS AND RESULTS: Prospective observational study of consecutive patients undergoing 2D and 3D transthoracic echocardiography (TTE), high-definition blood flow imaging, and cardiac magnetic resonance (CMR) within 1 h of each other. Left ventricular systolic function characterized by left ventricular end-systolic volumes and left ventricular end-diastolic volumes and LVEF were measured. Seventy-six patients were included. Correlation of 2D TTE with CMR was modest (r = 0.68) with a worse correlation in patients with three or more segments not visualized (r = 0.58). High-definition blood flow imaging was feasible in all patients, and the correlation of LVEF with CMR was excellent (r = 0.88). The differences between 2D, high-definition blood flow, and 3D TTE compared to CMR were 5 ± 9%, 2 ± 5%, and 1 ± 3%, respectively. The proportion of patients where the grade of LV function was correctly classified improved from 72.3% using 2D TTE to 92.8% using high-definition blood flow imaging. 3D TTE also had excellent correlation with CMR (r = 0.97) however was only feasible in 72.4% of patients. CONCLUSION: High-definition blood flow imaging is highly feasible and significantly improves the diagnostic accuracy and grading of LV function compared to 2D echocardiography.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Esquerda , Humanos , Volume Sistólico , Função Ventricular Esquerda , Reprodutibilidade dos Testes , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos
20.
Eur J Clin Invest ; 54(2): e14103, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37815038

RESUMO

BACKGROUND: Despite the availability of current antibiotic and surgical treatment options, infective endocarditis (IE) remains associated with a high mortality rate. Even though two-dimensional (2D) transesophageal echocardiography (TOE) is a major criteria in the diagnosis of IE, it is constrained by the single-plane orientation. Since three-dimensional (3D) TOE provides a comprehensive understanding of the cardiac architecture by allowing for a realistic visualization of the underlying structures in 3D space, it has attracted considerable interest in recent years. AIM: The purpose of this narrative review is to discuss the advantages and pitfalls of 3D TOE in patients with IE, as well as to address emerging photo-realistic 3D techniques that have the potential to enhance the visualization of cardiac structures in this setting. RESULTS: According to recent research, 3D TOE acquisitions outperform 2D acquisitions in terms of vegetation identification accuracy and embolism risk assessment. By reporting a variety of findings that are missed with 2D TOE, but which are validated by surgical examination, 3D TOE further improves the ability to identify endocarditis complications on both native and prosthetic valves. In addition to conventional 3D TOE, future developments in 3D technology led to the development of transillumination and tissue-transparency rendering, which may improve anatomical understanding and depth perception. Due to the use of both conventional and novel 3D techniques, there are more patients who require surgical intervention, indicating that 3D TOE may have a clinical relevance on the surgical management. CONCLUSION: 3D TOE might fill the gaps left by 2D TOE in the diagnosis of IE.


Assuntos
Ecocardiografia Tridimensional , Endocardite , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Endocardite/diagnóstico por imagem , Endocardite/complicações , Ecocardiografia Tridimensional/métodos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...